| Dimensions without packaging (H x W x D) | Basic dimensions (excluding the parts protruding from the body): 35 mm x 210.0 mm x 130.0 mm (1.38 in. x 8.27 in. x 5.12 in.)
Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 36.5 mm x 210.0 mm x 131.7 mm (1.44 in. x 8.27 in. x 5.19 in.) |
| Chassis height | 0.8 |
| Installation type | Desk mounting,Wall mounting |
| Weight without packaging | 1.11 (2.45) |
| Typical power consumption | 11 |
| Static power consumption | 4 |
| 100% power consumption | 11 |
| Maximum number of physical ports on the entire device | 10 |
| Long-term operating temperature | 0°C to 40°C (32°F to 104°F) at an altitude of 0-1800 m (0-5906 ft.) |
| Restriction on the operating temperature variation rate | When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). |
| Storage temperature | –40°C to +70°C (–40°F to +158°F) |
| Long-term operating relative humidity | 5% RH to 95% RH (non-condensing) |
| Long-term operating altitude | 0–5000 m (0–16404 ft.) |
| Storage altitude | 0-5000 m (0-16404 ft.) |
| Power supply mode | Power adapter |
| Rated input voltage | Power adapter input: 100–240 V AC; 50/60 Hz
Power adapter output: 56 V DC |
| Input voltage range | Power adapter input: 90 V AC to 264 V AC; 47 Hz to 63 Hz |
| Service port surge protection | Common mode: ±4 kV |
| Power supply surge protection | Differential mode: ±6 kV; common mode: ±6 kV |